You are currently viewing Solar Electricity Generation System

Solar Electricity Generation System

Technology overview

Solar cells are the smallest units of a photovoltaic installation and convert light into current by the photoelectric effect. The individual solar cells are connected together in a module (in series connection).

In order to achieve a higher system voltage, modules are connected in Series, called a string. PV strings of a Solar PV array are electrically connected to array junction box with protection devices.

Grid-connected Inverter is an integrated system consisting of a solar charge controller and inverter which converts the direct current (DC) generated by the PV arrays to Alternating

Current (AC) which is fed to the LT panel.

Solar photovoltaic panels

The Photovoltaic modules used for solar pv power plant will be poly-crystalline in nature with a

Module Mounting Structure

The structure will be designed to allow easy replacement of any module and will be in line with the site requirement. Structure will designed for simple mechanical and electrical installation. It will support SPV module at given orientation, absorb and transfer the mechanical loads to the roof property. There will be no requirement of welding or complex machinery at site. The array structure will have tilt arrangement to adjust the plane of solar array for optimum efficiency

Grid tied inverter

A three phase grid connected PV inverter is used to connect the electric grid. Feeding power into grid involves conversion of the DC voltage from the PV array to grid compatible AC voltage.

Junction Box

Junction boxes will be dust, vermin and waterproof and made of FRP/ ABS plastic with IP65 protection. The terminals will be connected to copper bus bar arrangement of proper sizes. The junction boxes will have suitable cable entry points fitted with cable glands of appropriate sizes for both incoming and outgoing cables. Suitable markings will be provided on the bus bar for easy identification and cable ferrules will be fitted at the cable termination points for identification.

Cables

Solar cables are extremely robust and resist high mechanical load and abrasion. High temperature resistance and excellent waterproofing

characteristic provide a long service life to cables used in large scale projects. Connectors with high current capacity and easy mode of

assembly are to be used for the connections of the power plant cables.

Scope of Work
NEMS will provide a turnkey solution and the above pricing includes the following:

The following are excluded from this quotation:

Payment Terms:

Stage % of total payment Next steps
Advance payment (upon order confirmation)
30%
Net Metering & Dispatch invoice
Dispatch of material
65%
Installation
Completion of installation
5%
Commissioning/connection of Meter

Please let me know in case any clarifications are required on this proposal. I look forward to taking this ahead post your confirmation.

Regards,

NEMS
Business

+91 8878803730

Renewable Energy System

Based on the source of renewable energy, renewable energy systems can be categorized as:

Use of Solar PV System for Outdoor Lighting

Solar PV system for outdoor lighting should be installed such that a minimum of 25% of the total number or 15% of the total connected load of outdoor lighting fixtures (whichever is higher) should be powered by solar energy.

Renewable Energy Generation System Capacity

A renewable energy system shall be installed in the building and its rated capacity shall be equal to or more than 1% of internal lighting and space-conditioning connected loads.

It is recommended that the installed renewable energy system meets the annual energy requirements of equal to or more than 30% of internal lighting connected loads or its equivalent in the building.

Renewable Energy Based Water Heating System Capacity

Residential facilities, hotels and hospitals with a centralized system shall have solar water heating for at least one-fifth of the design capacity.

It is recommended that the capacity of the hot water system is such that the annual energy saved by proposed renewable energy system is more than 70% of annual energy required for water heating to meet the hot water requirements of the occupants in the building.

Exception to above

If the hot water requirement is less than 500 litres per day.

System Efficiency

Solar water heater shall meet the performance/ minimum efficiency level mentioned in IS 13129 .

ater heater shall meet the performance/ minimum efficiency level mentioned in IS 13129

Proposal for 15 KW Grid-Tiled Rooftop Solar PV System

Summary of Proposal

Dear Sir,

Pursuant to our discussion, please find below the broad system specification as per your requirement. Detailed specifications including system layout will follow post order confirmation.

Configuration Solar PV System
15 KW Grid-Tied Rooftop
Project location
Gwalior M.P.
Project capacity
15 KW
Connection type
LT, Three phase
Roof type
RCC
Total Installation Cost
9.00 Lac
Elevated Structure Exclusive
Tax @ 5%
₹45000.00
Total installation costincl. 5% GST
9.5 lac
Net Metering Facilitation Charge
Inclusive
Total Cost
Rs.9.45 Lac
Freight
Inclusive
Sanction Load Up-gradation
Exclusive as per actual

Bill of Material

Component Make Quantity Technical Specification
Solar panels Vikram/Adani45325/330/335 Wp,Vmp-36.85, Imp-8.82,Voc-45.35
Inverter Luminous/Havells 115KW
Mounting structure Standard As Required Hot Dipped G.I./ Aluminum with SS304 nut bolts
MC4 connectors JMV As Required IP65, Compatible 325/330Wp
DC cable Polycab As Required ISO 9001/ISO 14001 /OHSAS 1000 VAC, 1800 V DC,1.5 KvDC
AC cable Polycab As Required IS 7098 Part - 1 Certified/ISO-9001:2008/ISO14001:2004
DC Distribution Box JMV (Components: Schindler) 1IP65
AC Distribution Box JMV (Components: Schindler) 1IP65
Earthing cable Polycab AsCopper
Solar Generation MeterSecure 1--
Bi-directional meter Secure 1--
Lightning arrestor JWV1--
Earthing Kit JWVAs Required ISO, CE, RoHS UL Certified
UPVC Pipe Kissan As Required ISO Certified